    Items: 0 New items: 39
    004110809
    New
    NHU01XL/150 aR 50A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    280
    Power dissipation (0,7x In) (W):
    8
    004110810
    New
    NHU01XL/150 aR 63A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    500
    Power dissipation (0,7x In) (W):
    9
    004110811
    New
    NHU01XL/150 aR 80A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    770
    Power dissipation (0,7x In) (W):
    13
    004110812
    New
    NHU01XL/150 aR 100A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    2.000
    Power dissipation (0,7x In) (W):
    10
    004110813
    New
    NHU01XL/150 aR 125A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    3.300
    Power dissipation (0,7x In) (W):
    12
    004110814
    New
    NHU01XL/150 aR 160A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    5.800
    Power dissipation (0,7x In) (W):
    15
    004110815
    New
    NHU01XL/150 aR 200A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    10.500
    Power dissipation (0,7x In) (W):
    18
    004110816
    New
    NHU01XL/150 aR 250A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    16.200
    Power dissipation (0,7x In) (W):
    23
    004110817
    New
    NHU01XL/150 aR 300A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    22.000
    Power dissipation (0,7x In) (W):
    28
    004110840
    New
    NHU1/110 aR 63A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    200
    Power dissipation (0,7x In) (W):
    5,5
    004110841
    New
    NHU1/110 aR 80A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    300
    Power dissipation (0,7x In) (W):
    6,9
    004110842
    New
    NHU1/110 aR 100A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    500
    Power dissipation (0,7x In) (W):
    9,2
    004110843
    New
    NHU1/110 aR 125A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    1.000
    Power dissipation (0,7x In) (W):
    10,8
    004110844
    New
    NHU1/110 aR 160A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    2.000
    Power dissipation (0,7x In) (W):
    14,9
    004110845
    New
    NHU1/110 aR 200A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    4.000
    Power dissipation (0,7x In) (W):
    16,7
    004110846
    New
    NHU1/110 aR 250A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    9.000
    Power dissipation (0,7x In) (W):
    21
    004110847
    New
    NHU1/110 aR 315A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    16.000
    Power dissipation (0,7x In) (W):
    25,8
    004110848
    New
    NHU1/110 aR 350A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    23.500
    Power dissipation (0,7x In) (W):
    25,2
    004110849
    New
    NHU1/110 aR 400A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    31.000
    Power dissipation (0,7x In) (W):
    28,8
    004110860
    New
    NHU1/110/M aR 63A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    200
    Power dissipation (0,7x In) (W):
    5,5
    004110861
    New
    NHU1/110/M aR 80A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    300
    Power dissipation (0,7x In) (W):
    6,9
    004110862
    New
    NHU1/110/M aR 100A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    500
    Power dissipation (0,7x In) (W):
    9,2
    004110863
    New
    NHU1/110/M aR 125A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    1.000
    Power dissipation (0,7x In) (W):
    10,8
    004110864
    New
    NHU1/110/M aR 160A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    2.000
    Power dissipation (0,7x In) (W):
    14,9
    004110865
    New
    NHU1/110/M aR 200A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    4.000
    Power dissipation (0,7x In) (W):
    16,7
    004110866
    New
    NHU1/110/M aR 250A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    9.000
    Power dissipation (0,7x In) (W):
    21
    004110867
    New
    NHU1/110/M aR 315A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    16.000
    Power dissipation (0,7x In) (W):
    25,8
    004110868
    New
    NHU1/110/M aR 350A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    23.500
    Power dissipation (0,7x In) (W):
    25,2
    004110869
    New
    NHU1/110/M aR 400A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    31.000
    Power dissipation (0,7x In) (W):
    28,8
    004110880
    New
    NHU3/110 aR 500A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    50.000
    Power dissipation (0,7x In) (W):
    37,4
    004110881
    New
    NHU3/110 aR 630A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    89.000
    Power dissipation (0,7x In) (W):
    48,5
    004110890
    New
    NHU3/110/M aR 500A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    50.000
    Power dissipation (0,7x In) (W):
    37,4
    004110891
    New
    NHU3/110/M aR 630A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-4
    Prearcing joule integral (A2s):
    89.000
    Power dissipation (0,7x In) (W):
    48,5
    004110800
    New
    NHU3L/150 gPV 300A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-6
    Prearcing joule integral (A2s):
    30.500
    Power dissipation (0,7x In) (W):
    19
    004110801
    New
    NHU3L/150 gPV 350A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-6
    Prearcing joule integral (A2s):
    48.000
    Power dissipation (0,7x In) (W):
    22
    004110802
    New
    NHU3L/150 gPV 400A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-6
    Prearcing joule integral (A2s):
    65.300
    Power dissipation (0,7x In) (W):
    24
    004110803
    New
    NHU3L/150 gPV 450A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-6
    Prearcing joule integral (A2s):
    89.000
    Power dissipation (0,7x In) (W):
    26
    004110804
    New
    NHU3L/150 gPV 500A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-6
    Prearcing joule integral (A2s):
    120.000
    Power dissipation (0,7x In) (W):
    29
    004110805
    New
    NHU3L/150 gPV 600A/1000V DC
    Class name:
    Fuse link
    Application:
    For protection on DC side of EV chargers
    Standards:
    IEC 60269-6
    Prearcing joule integral (A2s):
    350.000
    Power dissipation (0,7x In) (W):
    32
    >
    >
    0