Type some words to find content.
eg: fuse, arrestor, 00110115 technical, MCCB...
Recent searches
Tehnical support
This email address is being protected from spambots. You need JavaScript enabled to view it.
Filter type
Clear all
Expand all
Open all
Rated current (A)
2
2
2
2
2
2
2
3
2
Rated short-circuit making capacity Icm
2
4
4
4
3
2
Number of poles
10
9
Rated short-time withstand current Icw at 0,3s (kA)
2
4
4
4
3
2
19

ED2

Items: 0
004671271
ED2 125/3
Class name:
Switch disconnector
Rated current (A):
125
Rated short-circuit making capacity Icm:
3,6
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
2
004671272
ED2 160/3
Class name:
Switch disconnector
Rated current (A):
160
Rated short-circuit making capacity Icm:
6
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
3
004671273
ED2 250/3
Class name:
Switch disconnector
Rated current (A):
250
Rated short-circuit making capacity Icm:
6
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
3
004671274
ED2 400/3
Class name:
Switch disconnector
Rated current (A):
400
Rated short-circuit making capacity Icm:
9
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
5
004671275
ED2 630/3
Class name:
Switch disconnector
Rated current (A):
630
Rated short-circuit making capacity Icm:
9
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
5
004672370
ED2 800/3
Class name:
Switch disconnector
Rated current (A):
800
Rated short-circuit making capacity Icm:
17
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
10
004672373
ED2 1000/3
Class name:
Switch disconnector
Rated current (A):
1000
Rated short-circuit making capacity Icm:
17
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
10
004672371
ED2 1250/3
Class name:
Switch disconnector
Rated current (A):
1250
Rated short-circuit making capacity Icm:
32
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
15
004672374
ED2 1250/3 PI 3C
Class name:
Switch disconnector
Rated current (A):
1250
Rated short-circuit making capacity Icm:
32
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
15
004672372
ED2 1600/3 FC
Class name:
Switch disconnector
Rated current (A):
1600
Rated short-circuit making capacity Icm:
45
Number of poles:
3
Rated short-time withstand current Icw at 0,3s (kA):
20
004671276
ED2 125/4
Class name:
Switch disconnector
Rated current (A):
125
Rated short-circuit making capacity Icm:
3,6
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
2
004671277
ED2 160/4
Class name:
Switch disconnector
Rated current (A):
160
Rated short-circuit making capacity Icm:
6
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
3
004671278
ED2 250/4
Class name:
Switch disconnector
Rated current (A):
250
Rated short-circuit making capacity Icm:
6
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
3
004671279
ED2 400/4
Class name:
Switch disconnector
Rated current (A):
400
Rated short-circuit making capacity Icm:
9
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
5
004671280
ED2 630/4
Class name:
Switch disconnector
Rated current (A):
630
Rated short-circuit making capacity Icm:
9
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
5
004672380
ED2 800/4
Class name:
Switch disconnector
Rated current (A):
800
Rated short-circuit making capacity Icm:
17
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
10
004672383
ED2 1000/4
Class name:
Switch disconnector
Rated current (A):
1000
Rated short-circuit making capacity Icm:
17
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
10
004672381
ED2 1250/4
Class name:
Switch disconnector
Rated current (A):
1250
Rated short-circuit making capacity Icm:
32
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
15
004672382
ED2 1600/4 FC
Class name:
Switch disconnector
Rated current (A):
1600
Rated short-circuit making capacity Icm:
45
Number of poles:
4
Rated short-time withstand current Icw at 0,3s (kA):
20
>
>
0